• Static Filter System for Gas Turbine
  • Static Filter System for Gas Turbine
  • Static Filter System for Gas Turbine
  • Static Filter System for Gas Turbine
  • Static Filter System for Gas Turbine
  • Static Filter System for Gas Turbine

Static Filter System for Gas Turbine

Clapboard: with Clapboard
Filter Number: 9~60
Medium Material: Fiberglass
Efficiency: H10~H12
Filtration Grade: HEPA Filter
Type: Perfilter , Filter Bag,HEPA Filter
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RH/KL
Brand
Ccaf
Cartridge Installation
Horizental
Airflow
Customize
Filter Efficiency
H10~H12
Certification
ISO9001& SGS& CE
Filter Type
3 Stage Filter
Filter Systems Design
Modular Design
Transport Package
Nude
Specification
RH/XLC
Trademark
CCAF
Origin
Jiangsu Province China
HS Code
84219990
Production Capacity
40set/Month

Product Description

Static filter system for Gas turbine

RH/KL TYPE
How to it work
Under the condition of the power units' intake negative pressure, RH/KL type filter intakes ambient air , when the air with dust goes through the filter,second and third-stage(fouth stage,if required) filter elements, the big particles in the air willbe filtered by the first and second-stage filter elements for the sake of the gravity and inertia force, the small size and low density o fthe dust will be filtered on the third and fourth-stage surface of filter media by the brownian diffusion, fiber intercept and other combined effect, then the filtered air flows into the clean room and past the outlet duct to power units
 

Feature
Static filter RH/KL type uses multistage panel filter elements the pre-filter is the solid-liquid inertial seperator under the weather hood.
First stage:G3 ~G4 filter elements , second stage:M5~M6 Filter bags, third stage:H10~H12 Filter elements,suitable for humid and foggy coastal zone with high density of moisture and dust. Multistage of filter elements can meet the request of desalting, the material of the filter can be stainless steel or painted carbon steel.

 
RH/HK  Technical specification

Type RH/KL-9 RH/KL-12 RH/KL-16 RH/KL-20 RH/KL-24 RH/KL-30 RH/KL-40 RH/KL-48 RH/KL-60
Air flow(m3/h) 13500
~30000
18000
~40000
24000
~54800
30000
~68000
36000
~81500
45000
~102000
60000
~136000
72000
~163200
90000
~204000
Filter class H10~H12
Initial resistance(<Pa) 200 200 200 200 200 200 200 200 200
Qty of first-stage filter elements 9 12 16 20 24 30 40 48 60
Qty of second-stage filte rbags 9 12 16 20 24 30 40 48 60
Qty of third-stage HEPA 9 12 16 20 24 30 40 48 60

 
Note:
1.Two materials of filter bags for your choice: chemical fiber and glass fbier.
     Chemical fiber is more environmental and glass fiber is good resistance to Moisture
2. HEPA: 4V and 5V-bank structure for you choice, also aluminum separator structure

 
Application:
Foggy,rainy,moist coastal zone,intake filtering of high-speed air compressor or air separator.
Diesel generatiing set, small size gas turbine
Especiclly offshore oil platfor.
Static Filter System for Gas TurbineStatic Filter System for Gas Turbine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.